CUISINE-SPECIFIC FIELD GUIDE
Commissary / Ghost Kitchen / Catering Conversion Inspection Manual
CUISINE-SPECIFIC LANDMINE
Pickup-door logistics + loading layout + per-tenant separation drive a wholly different code path.
EN + ES · free · link by email
One email with the link. We don’t sell your address; you can unsubscribe with one click.
WHERE THIS CUISINE QUIETLY COSTS YOU MONEY
Commissary / Ghost Kitchen / Catering-specific conversion gotchas
01 · Driver-pickup vestibule + queue
A multi-brand ghost kitchen at lunch peak can see dozens of drivers, so plan a separate pickup vestibule (200–400 sq ft is typical) with heated/cooled bagging shelves, a driver-ID screen, and one-way flow that doesn't cross prep. With one front door, drivers and staff share a single path — check exits and occupant load with the city early.
02 · Per-tenant separation
Health departments differ on multi-tenant kitchens: if each brand operator holds its own food permit, expect to be asked for its own 3-compartment sink, hand sink and storage, so ask the health department whether tenants may share before you lay out stations. Plan 6–8 ft of plumbing rough-in per tenant station (typically $8K–$15K per slot).
03 · Loading dock + commissary deliveries
A commissary runs 3–5 deliveries/day (produce, dairy, dry goods, paper). Without a dedicated loading dock or door-side staging area, deliveries cross the kitchen at the same time orders go out. Plan a 200–300 sq ft receiving zone with floor scale, fridge staging shelving, and a separate dock door.
04 · Pack-station + insulated-bag inventory
Catering and delivery require a pack zone with 8–12 ft of stainless table, label printer, sealable container storage, and 50+ insulated delivery bags ready at peak. Inherited spaces always under-allocate this — orders pile up at the expo line and food cools. Spec the pack zone equal in size to the cook line.
05 · POS + tablet aggregator stack
Ghost kitchens run 4–8 third-party aggregator tablets (Uber Eats, DoorDash, Grubhub, brand-direct, etc.). Each needs a 120V outlet, a network drop, and tablet-arm wall mount. Plan a tablet wall behind the expo line with dedicated outlets and structured cabling — pulling cables after the wall is finished is often a $3K rework.
Five immediate stop signals
These cancel any deal regardless of cuisine.
You smell gas, see burnt wiring, or see blackened / charred hood areas.
The exhaust fan is missing, disconnected, or shaking violently.
The seller refuses to provide hood / fire / grease records.
You must add major cooking equipment outside the existing hood.
The landlord will not allow roof, gas, electrical, or grease-interceptor work.
WALK
Smell, look, listen
PROVE
Hood · gas · electrical · plumbing
PRICE
Written scopes before signing
NEGOTIATE
Or walk away
Defined terms in this guide
The vocabulary worth knowing before you sign.
- Authority Having Jurisdiction· AHJ
- The local government body that issues building permits and enforces code in a specific jurisdiction — typically the city building department; the fire marshal and health department are AHJs for their parts.
- Americans with Disabilities Act· ADA
- Federal civil-rights law requiring accessible design in public accommodations; its design rules are the 2010 ADA Standards. Building departments separately enforce accessibility through IBC Chapter 11 / ICC A117.1 (California: CBC Chapter 11B).
- Occupant Load
- The IBC-prescribed maximum number of people permitted in a space. Calculated by dividing floor area by the factor in IBC Table 1004.5 — 15 net sq ft per person at tables and chairs, 7 for chairs only, 5 for standing space.
- Indirect Waste
- A drain that discharges to a floor sink with an air gap (not a direct connection to the sewer). Required for ice machines, food-prep sinks, and most refrigeration condensate lines.
- Capture Velocity
- The air speed needed at the hood edge to pull in rising cooking effluent. Codes set no single capture-velocity number: unlisted hoods use the mechanical code’s minimum CFM per linear foot (IMC 507), listed hoods their listed airflow, and a capture-and-containment test confirms it.
OTHER CUISINES
18
Fried Chicken / Wings / Quick-Service Fry
Fryer banks mean heavy grease washdown — check the existing grease interceptor against your city's sizing rules before you sign.
02
Mexican / Tex-Mex
Comal + plancha lines and tortilla warmers are usually under-vented in inherited TI shells.
06
Pizza / Italian
Deck/wood-fired oven weight and venting are show-stoppers in mid-floor TI spaces.
Already walking the space?
After your field findings come the permit drawings. We don’t take restaurant jobs ourselves — send us the address and we’ll refer you to a registered architect. We reply within one business day.